Product Description

UZ210*: Signal Converter Analogue (V, I) to SSI (Position), Incremental (Position &  Frequency) and to  Serial RS232 / RS485

[PDF manual]
  • High performance universal converter for analogue input signals with excellent features and multiple conversion modes.
  • Input range:-10V…+10V / 0/4…20mA
  • Conversion time max. 250 us
  • Quadrature frequency outputs HTL or TTL (A,/A, B,/B, Z,/Z) from 0,01 Hz up to 1 Mhz
  • Incremental encoder output and SSI interface, for digital expression of
    linear or angular positions as a result of analogue inputs
  • Incremental direction signal A/B depending on polarity  of input signal and parameter settings
  • Programmable marker impulse output (Z, /Z)
  • Various user modes: Programmable V / f characteristics,  programmable curves with optionally repeating curve cycles, additional control functions similar to a “motorized potentiometer”
  • USB, RS232 and RS485 interface for programming and serial readout of the conversion result and other internal registers
  • Adjustable filter functions as well as operator programmable linearization curves
  • Printer mode for automatic data transfer of internal registers to a data logger or PC
  • For 115/230 VAC supply and A-A type USB cable see accessories
Voltage-to-Frequency Converter V/f and  Analogue to SSI
 ______________________________________________________________________

UF251*: Signal Converter Analogue (V, I) to Frequency and
to  Serial RS232 / RS485

[PDF manual]
  • High performance analogue-to-frequency and analogue-to-serial  converter
  • Input range:-10V…+10V / 0/4…20mA
  • Conversion time approx. 1ms only
  • Quadrature frequency outputs HTL (A/B/Z) from 1 Hz to 100 kHz and
    TTL differential / RS422  (A,/A, B,/B, Z,/Z)  from 1 Hz to 500 kHz
  • Phase A/B depending on polarity of input signal, marker pulse output with programmable distance.
  • Various user modes: Programmable V / f characteristics, Motorized potentiometer function, cyclic frequency output curves etc.
  • RS232 and RS485 interface for serial readout of the conversion result and other internal registers
  • Adjustable floating average filter as well as operator programmable linearization curves
  • Printer mode for automatic data transfer of internal registers to a data logger or PC
  • For 115/230 VAC supply see accessories
Voltage-to-Frequency Converter V/f

Please note that also some of our Process Indicator Units are suitable for
analogue-to-serial conversion (see “Panel Meters”)